Acros Brocade 48000 Manual [Unlimited EBooks]

Bike Brand: 
Bike Category: 
Road
Brocade 48000 Manual [Unlimited EBooks]
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF


File Name:Brocade 48000 Manual [Unlimited EBooks].pdf
Size: 1955 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 21 May 2019, 19:48 PM
Rating: 4.6/5 from 831 votes.

Status: AVAILABLE


Last checked: 2 Minutes ago!

In order to read or download Brocade 48000 Manual [Unlimited EBooks] ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version



✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers


Brocade 48000 Manual [Unlimited EBooks]

Page Count: 122 Brocade 48000. Hardware Reference Manual. Supporting Fabric OS v6.1.0. All Rights Reserved. Brocade, the Brocade B weave logo, Fabric OS, File Lifecycle Manager, MyView, Secure Fabric OS, SilkWorm, and StorageX areFICON is a registered trademark of IBM Corporation in the U.S. and other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products orNotice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerningBrocade reserves the right to make changes toThis informational document describesContact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government. The authors and Brocade Communications Systems, Inc.The product described by this document may contain “open source” software covered by the GNU General Public License or otherTo find-out which open source software is included in Brocade products, view the licensingCorporate Headquarters. Brocade Communications Systems, Inc.San Jose, CA 95110. Tel: 1-408-333-8000. Fax: 1-408-333-8101. Asia-Pacific Headquarters. Brocade Communications Singapore Pte. Ltd.Singapore 048619. European and Latin American Headquarters. Brocade Communications Switzerland Sarl. Centre Swissair. Tour A - 2eme etageCase Postale 105. CH-1215 Geneve 15. Switzerland. Document History. Title. Publication Number. Summary of Changes. Date. Brocade 48000 Hardware Reference. ManualMarch 2005. ManualFebruary 2006. ManualOS v5.2.0 features andSeptember 2006. ManualOS v5.3.0 and supportedBrocade 48000 Hardware Reference. ManualFabric OS v6.0.0. January 2008. ManualFabric OS v6.1.0. March 2008. Brocade 48000 Hardware Reference ManualBrocade 48000 Hardware Reference ManualAbout This Document. How this document is organized............................. xi.

http://www.zajazdszalas.pl/userfiles/98-toyota-camry-repair-manual.xml

    Tags:
  • brocade 48000 manual, brocade 48000 manual pdf, brocade 48000 manual download, brocade 48000 manual free, brocade 48000 manual instructions.

Supported hardware and software.......................... xii. Chapter 1. Overview. Brocade 48000 Director features............................ 1. Nonport side of the director............................. 4. Brocade 48000 Hardware Reference ManualInstallation. Site preparation, unpacking the director, and safety............ 10. Items included with the director.............................12. Providing power to the director............................. 13. Chapter 3. Log In and Configuration. Establishing a serial connection and logging on to director......18. Establishing an Ethernet connection.........................20. Verifying the PID mode and connecting to the fabric............ 21. Chapter 4. Monitor System Components. Determining the status of a port or application blade...........25. Determining the status of a control processor blade (CP4)...... 37. Determining the status of a power supply.....................39. Determining the status of a blower assembly.................. 41. Determining the status of the WWN card.....................42. Chapter 5. Removal and Replacement Procedures (RRPs). RRP: Port and application blade............................48. RRP: Control processor blade (CP4).........................56Brocade 48000 Hardware Reference ManualRRP: WWN bezel and WWN card............................67. Appendix A. Specifications. System blade and FRU weights.............................75. Fibre Channel port specifications...........................80. MIC statement (Republic of Korea)......................82. Regulatory compliance standards.......................83. Environmental regulation compliance........................84. Appendix B. Application Blades. Appendix C. Diagnostics and Troubleshooting. Brocade 48000 Hardware Reference ManualInterpreting POST and boot results..........................92Chapter D. Port Numbering Template. IndexBrocade 48000 Hardware Reference ManualAbout This Document. In this chapter.

http://ahzfgroup.com/uploads/file/2020/09/080248105796.xml

How this document is organized. This document is a hardware reference manual written for system administrators and techniciansThis document presents information on setting-up and operating the director. It is organized in aThe document contains the following sections:Brocade 48000 Hardware Reference ManualSupported hardware and software. This document includes information specific to the director running Brocade Fabric OS versionThe following change has been made since this document was last released. Document conventions. This section describes text formatting conventions and important notices formats. Text formatting. The narrative-text formatting conventions that are used in this document are as follows:Identifies command names. Identifies GUI elements. Identifies keywords and operands. Identifies text to enter at the GUI or CLIProvides emphasis. Identifies variables. Identifies paths and Internet addresses. Identifies document titlesIdentifies CLI output. Identifies syntax examples. For readability, command names in the narrative portions of this guide are presented in mixedIn actual examples, command lettercase is often allBrocade 48000 Hardware Reference ManualAdditional information. This section lists additional Brocade and industry-specific documentation. Brocade resources. The following related documentation is provided on the Brocade Documentation CD-ROM and onFabric OS. Fabric OS Optional Features. Web Tools Administrator’s Guide. Fabric Watch Administrator’s Guide. Fabric Manager Administrator’s Guide. Secure Fabric OS Administrator’s Guide. Brocade 48000. Control Processor Blade Replacement Procedure. Blower Assembly Replacement Procedure. Cable Management Tray and Guide Replacement Procedure. Chassis Door Replacement Procedure. WWN Bezel and Card Replacement Procedure. Power Supply and Filler Panel Replacement ProcedureRelease Notes are available on the Brocade Connect Web site and are also bundled with the Fabric. OS firmware.

https://www.interactivelearnings.com/forum/selenium-using-c/topic/18747/datamax-dmx-i-4208-manual-pdf

For practical discussions about SAN design, implementation, and maintenance, you can purchase. Building SANs with Brocade Fabric Switches through:Library location:Other industry resources. In addition to this manual, the following information about fabric security and the Secure Fabric OSThis Web siteChannel, storage management, and other applications:Contact your director supplier for hardware, firmware, and software support, including productTo expedite your call, have the following information available:Technical Support contract number, if applicable. Director model. Director operating system version. Error numbers and messages receivedDetailed description of the problem and specific questions. Description of any troubleshooting steps already performed and results. Serial console and Telnet session logsThe director serial number and corresponding bar code are provided on the serial numberBrocade 48000 Hardware Reference ManualThe serial number label is located inside the front of the chassis, on the wall to the left of theUse the licenseIdShow command to display the license ID. Document feedback. Because quality is our first concern at Brocade, we have made every effort to ensure the accuracyHowever, if you find an error or an omission, or you think thatForward your feedback to. Provide the title and version number and as much detail as possible about your comment,General precautions. When installing or servicing the director, follow these practices. ESD precautions. The director contains electrostatic discharge (ESD) sensitive FRUs. When working with anyAttention notices. An attention notice indicates the possibility of damage to a program, device, or system, or toBrocade 48000 Hardware Reference ManualSafety noticesCD-ROM that accompanies this product. When using this product, observe the danger, caution, and attention notices in this manual.

http://elreehavia.com/images/cancasexl-log-manual.pdf

TheThe danger and caution notices are listed in numerical order based on their IDs, which areUse this ID to locate theA danger notice calls attention to a situation that is potentially lethal or extremely hazardous toRead and comply with the following danger notice before installing orEnsure the facility power receptacle is the correct type, suppliesCaution notices. A caution notice calls attention to a situation that is potentially hazardous to people becauseBrocade 48000 Hardware Reference ManualIn this chapterThe Brocade 48000 Director represents the next generation of advanced Fibre Channel directorsIt satisfies the most demanding Reliability, Availability, and Serviceability (RAS), performance, andKey features of the director include:Trunking technology groupsBrocade 48000 Hardware Reference ManualHardware components. The director features a modular and scalable mechanical construction that allows a wide range ofThe chassis may be mounted with theRouting Services and FCIPFigure 1 displays a sample configuration of the port side of the director.LinkActive CPPort side of the director (sample configuration). Brocade 48000 Hardware Reference ManualNonport side of the director. Figure 2 displays a sample configuration of the nonport side view of the director.WWN Bezel. Power Supply LEDs. Blower Power LED. Blower Fault LEDNonport side of the director (sample configuration). Brocade 48000 Hardware Reference ManualTable 1 summarizes the port, application, and control processor blades that are available for theDescription. Name. Function. Brocade 48000This control processor bladeGbps port speeds. This port blade is compatible only with the. Brocade 48000 Director or Brocade DCX.Gbps port speeds. This port blade is compatible only with the. Brocade 48000 Director or Brocade DCX.This port blade is compatibleFibre ChannelEthernet copper interfaces supporting blade management. ThisDirector or Brocade DCX. Fibre Channel routerFR4-18i.

https://www.leesii.com/wp-content/plugins/formcraft/file-upload/server/content/files/16344f31613394---d33032-motherboard-manual.pdf

A blade that has 16 physical Fibre Channel SFP ports supporting. Fibre Channel Routing Services and 2 physical Gigabit EthernetEthernet (GbE) copper RJ-45 ports. Brocade 48000 Hardware Reference ManualHigh availability. The following features contribute to the director high-availability design. Redundant, hot-swappable blades and FRUs. Enhanced data integrity on all data paths. Fabric Shortest Path First (FSPF) rerouting around failed links. Integration with Simple Network Management Protocol (SNMP) managers. Automatic control processor failover. Nondisruptive “hot” software code loads and activation. Easy configuration, save, and restore. Hot-swappable World Wide Name (WWN) card. The high-availability software architecture of the director provides a common framework for allHigh-availability elements consist of the High Availability Manager, theThe High Availability Manager controls access to the standby control processor, facilitates softwareReliability. The director uses the following error detection and correction mechanisms to ensure reliability ofServiceability. The director provides the following features to enhance and ensure serviceability:Background health-check daemon. Memory scrubber, self test, and bus ping to determine if a bus is not functioning. RASlog messages. SMI-S compliant. Watchdog timers. Status LEDs. Predictive diagnostics analysis through Fabric Watch. SNMP (including version 3) integration with higher-layer managers. Software features. The Fabric OS allows any Fibre Channel-compliant device to attach to the switches as long as itEach operatingFabric OS consists of a set of embedded applications running on top of an embedded LinuxThese applications include. Name server. Alias server. Zone server. Simple Network Management Protocol (SNMP) agent. SMI-S compliant API. Syslog auditing. RCS (Reliable Commit Service)Security.

chooset.com/galeria/files/Dialysis-Billing-Manual.pdf

Table 2 highlights some of the key security features available for the director and for other BrocadeBrocade White Paper, “The Growing Need for Security in Storage Area Networks”. Brocade 48000 Hardware Reference ManualBrocade Security FeaturesSSHv2 (using AES, 3DES, RSA). Monitoring of attempted security breachesHTTPS (using AES). Monitoring of attempted security breachesSNPMv3. Fibre Channel security policies: DCC and SCCSecure RPC. Management access controls (SNMPv3. Telnet, FTP, serial port, front panel). Secure file copy (SCP). Hardware-enforced zoning by WWN. Telnet disable. Default zoning. Telnet timeout. RSCN suppression and aggregation. IP filters (block listeners). Configurable RSCN suppression by port. Secure passwords (centralized control. NTPv3 (to synchronize timestamps). Multiple user accounts (MUAs). Up to 255. Event auditing. Role-based access controls (RBACs). Change tracking. Firmware change alerts in Fabric Manager. Boot PROM password reset. Persistent port disable. Password hardening policies. Persistent domain ID. Upfront login in Web Tools. Network manageability. The director has a single domain and is managed as a single element with the Enterprise Fabric. The director responds to its own IP addressAll management interfaces, such as Telnet, Web Tools, standards compliant SMI-S, and. Management Server, support a “port N within blade M” naming scheme. The director supports SNMPv1 and SNPMv3. When SNMP devices send SNMP messages to aFabric OS v6.0.0 supports the latest Fibre Alliance Fibre. Channel Management (FCMGMT) and Storage Management Initiative (SMI) MIBs, which allowIn this chapter. Time and items required. You can set up and install the Brocade 48000 Director in the following ways:This chapter describes how to set up the director as a standalone unit. For rack-mount installationInstallation Procedure.

https://cageart.ca/wp-content/plugins/formcraft/file-upload/server/content/files/16344f337e147f---d3222-b-manual.pdf

Table 3 describes the main installation and setup tasks and the estimated time required for each,Configurations with fewer portsInstallation task. Time estimate. Items required. Site preparation and unpacking directorPallet jack. Hydraulic lift or assisted lift, able to raise to aThe directorInstalling rack mount kitMounting and securing director in rackRefer to the 14U Rack Mount Kit Installation. Procedure or the Mid-Mount Installation. Procedure. Brocade 48000 Hardware Reference ManualInstallation task. Installing power cables and powering onPower cables and serial cable (provided in theInstalling SFP and XFP (10-Gbps) opticalSFP and XFP (10-Gbps) optical transceivers. Attaching fiber optic cables, cable ties, andFiber optic cables, cable ties, and pillars. Establishing serial connection, logging onSerial cable (provided in the director accessoryWorkstation computer with a serial port orEthernet IP addresses for the switch (1) andInstalling one or more Ethernet cables andEthernet cabling (optional) for Telnet access. All other configuration parameters optional. Refer to the Fabric OS Administrator’s GuideSite preparation, unpacking the director, and safetyThe following steps are required to ensure correct installation and operation.The director can beCables can be managed in a variety of ways, such as by routing cables below the chassis, toCut the bands that encircle the packaging.Remove the lid and the kits and foam from the top of the chassis.Lift the cardboard box off the chassis and remove the plastic bag from around the chassis. Save the packing materials for use when returning the old chassis.Leave the chassis on top of the plastic shipping tray if the chassis must be transported toThe chassis sitsDoorways must be wider than 36 in. (91 cm) to accommodate the chassis.If installing the chassis in a cabinet, follow theBrocade 48000 Hardware Reference ManualItems included with the director.

https://www.partyshuttlebus.com.au/wp-content/plugins/formcraft/file-upload/server/content/files/16344f351cbfff---d33025-intel-motherboard-manual.pdf

The following items are included with the standard shipment of the director. The RS-232 cable has an adapter at one end that can be removed toOrder the optical transceivers (SFP and XFP) from Brocade. The director supports SWL, LWL, and. ELWL transceivers.Providing power to the directorEnsure the facility power receptacle is the correct type, suppliesThese clear plastic coversAC switches from being powered on or off accidentally (Figure 3).Orient a retainer against the AC panelRepeat for the other retainer. The power cord retainers areAC Power receptacle. Jack screw. Clamping screwPower cord retainer. Retainer attaching screw. Clamping screw. AC panel and power cord retainersThe power cords areBrocade 48000 Hardware Reference ManualThe director performs a power-on self-test (POST) each time it is powered on. POST takesComponents”. You can bypass POST by using the fastBoot command. You can also disable POST forIP addresses are configured (Chapter 3, “Log In and Configuration”).Port numbering. The director uses the following port numbering method (Appendix D, “Port Numbering Template”).At the bottom ofSlots are numbered 1 through 10, from left to right when facing the port side of the director. Control processor blades (CP4) can be installed only in slots 5 and 6.The cable management tray (Figure 4) is attached to the chassis under the chassis door and allowsThe tray can be installed without service disruption. Route cables down in front of the blades to keep LEDs visible. Leave at least one meter of slack forIf ISL Trunking is in use, group the cables by trunking group. The ports are color-coded to indicateSee Table 7 for a listing of supported cableLinLinAcAcCablesCable Management Tray. Cable management tray. Brocade 48000 Hardware Reference ManualBrocade 48000 Hardware Reference ManualIn this chapterThe Brocade 48000 Director must be configured before it is connected to the fabric, and all of theThe director configurationIP address and subnet mask for the chassis.

BANGTUTRANG.COM/upload/files/Diablo-3-Manual-Pdf-Ps3.pdf

IP addresses, host names, subnet masks, and gateway addresses for both CP blades. Switch name. Domain ID for the director (optional). WWN for the director. The director WWN is initially set by the factory to match the license ID (which is based on theThe WWN can be changed but the license ID cannot be modified. The configuration information is mirrored to the standby CP blade, which allows the currentThe configuration information forThe configurationThe basic steps required for the initial configuration are:Brocade 48000 Hardware Reference ManualEstablishing a serial connection and logging on to directorUse the serial cableWindows environment or TERM in a UNIX environment).For most MS Windows systems. Bits per second. Databits. Parity. Stop bits. Flow control:For most UNIX systems, type the following string at the prompt. When the terminal emulator application stops reporting information, press Enter. You willCP0 Console Login:The default password is “password”. At the initial login, theMake sure to write down the newFabric OS (swDir)Password. Please change your passwords now. Use Control-C to exit or press 'Enter' key to proceed. Password was not changed. Will prompt again at next loginPasswords can be 8 to 40 characters long. They must begin withThey can include numeric characters, the dot (.), and the underscoreConfiguring IP addresses. The director requires three IP addresses, which are configured using the ipAddrSet command. IPWatch, SNMP, or other applications can cause traffic to be interrupted or stopped.Enter the information at the prompts. Specify the -sw 0 IP address. There is no -sw 1 IPExternal IPs must not use these addresses.Enter the information at the prompts.Enter the information at the prompts. This is a sample IP configuration. Brocade 48000 Hardware Reference ManualIssuing gratuitous ARP.Done. Committing configuration.Done. IP address is being changed.Done. IP address of remote CP is being changed.Done. Committing configuration.Done.

Establishing an Ethernet connectionBy establishing an Ethernet connection, you can complete the director configuration using a serialThe director can be accessed by remote connection using any of the management tools, suchThe default password is “password”.The switch name of the director can be up to 15 characters long; can include alpha, numeric, andCommitting configuration. Done.Setting the Domain ID. Each switch in the fabric must have a unique Domain ID. The Domain ID can be manually set withThe default Domain ID for the director is “1”. Use the fabricShow command to view the already assigned domain IDs.Verifying the PID mode and connecting to the fabric. Before connecting the director to the fabric, verify that the port identifier (PID) mode on the directorThis parameter must be identical for all switches in theThe ports are color-coded to indicate which can be used in the same port group for trunkingThe ports and cables used in trunking groups mustRefer to the Fabric OS Administrator’s Guide. Brocade 48000 Hardware Reference ManualTransceivers are keyed so that they can only be inserted with the correct orientation. If aInsert the cable into the transceiver until the latching mechanismCables are keyed so that they can be inserted in only one way. If a cable does not slide inSoftware licenses. Depending on the vendor agreement, certain licenses are factory installed on the director. ToAAbbccDDeeFFeeGG. Web license. Zoning license. Extended Fabric license. Fabric Watch license. Performance Monitor license. Trunking license. Security license. In this example, the license key is AAbbccDDeeFFeeGG. Keep a copy of the license key forThe 64-bit chassis ID is required to obtain and activate licenses for the director. The chassis ID isThe licenseShow and licenseIdShow commandsRefer to the Fabric OS Administrator’s Guide. Configuration backup.

Save all key configuration data for the director, including license key information, and upload it to aAfter zoning configurations and other changes are complete, back up the configuration by typingThis command uploads the director configuration to the server so thatAn easy way to back up configuration information is to enable logging on your Telnet session; thenKeep copies of key data such as passwords, license keys, and IP addresses in a secure location.Brocade 48000 Hardware Reference ManualBrocade 48000 Hardware Reference ManualIn this chapterThe Brocade 48000 Director is engineered for reliability and requires no routine operational stepsRefer to the Web Tools Administrator’s Guide and the. Fabric OS Administrator’s Guide for additional information. Determining the status of a port or application bladeFigure 5 illustrates the FC8-16 port blade. Figure 6 illustrates the FC8-32 port blade. Figure 7 illustrates the FC8-48 port blade. Figure 8 illustrates the FC4-16 port blade. Figure 9 illustrates the FC4-32 port blade. Figure 10 illustrates the FC4-48 port blade. Figure 11 illustrates the FC10-6 port blade. Figure 12 illustrates the FC4-16IP application blade. Figure 13 illustrates the FR4-18i application blade. Figure 14 illustrates the FA4-18 application blade.Brocade 48000 Hardware Reference ManualStatus LEDPort Status LED. FC8-16 Port blade. Brocade 48000 Hardware Reference ManualStatus LEDPort Status LED. FC8-32 Port blade.

EN 61000-4-8 Magnetic Fields. EN 61000-4-11 Voltage Dips and Interruptions. EN 61000-3-2 Limits for Harmonic Current Emissions. EN 61000-3-3 Flicker. International. EN55022 Class A. Japan. EN 61000-3-2 Harmonics (JEIDA Limits)Country.

Bike Model Name: 
Brocade 48000 Manual [Unlimited EBooks]