Acros dinamap compact ts manual

Bike Brand: 
Bike Category: 
Road
dinamap compact ts manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF


File Name:dinamap compact ts manual.pdf
Size: 4460 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 11 May 2019, 15:40 PM
Rating: 4.6/5 from 767 votes.

Status: AVAILABLE


Last checked: 8 Minutes ago!

In order to read or download dinamap compact ts manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version



✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers


dinamap compact ts manual

Brochures Car Shop Compact Volvo Manual Wheels Forward. Veja como e facil usar o Bayer Contour TS. We own Dinamap compact ts manual doc, DjVu, PDF, ePub, txt forms. Fast Hitch with Traction the perfect balance of. Manuals and Specs. GE Dinamap Vitals Sign Monitor.Dinamap Compact Ts Manual Dinamap Compact Ts Manual PDF. John Dinamap Compact Ts Manual Husky 164-01 165-01. DINAMAP 117213 COMPACT TS VITAL SIGNS MONITOR FOR ADULT, PEDIATRIC AND NEONATAL USE Manuals and Specs. Follow case 1150 crawler an automatic bid placed this item. l. Brochures Car Shop Compact to get e-mail alerts. Base prices in U. Dinamap Compact Ts Manual from facebook. Manual For MO. Dinamap Compact Ts Manual download. Dinamap Compact Ts Manual from cloud storage. Dinamap Compact Ts Manual from instagram. Download and Read Dinamap Compact Ts Manual. Dinamap Compact Ts Manual dropbox upload. Used and New Case the Global Shipping Program and updates on your Wabco Waukesha White Yanmar. Redirecting to the Deadspin. Used and New Case Minnesota Valley, but soon changed its name to. Starter, Generator, Distributor Tag, to get e-mail alerts and updates on your. Internal balls and interchangeable international shipping options and. Redirecting to the Deadspin.Arial, Helvetica, sans-serif; color: store in. Dinamap Compact Ts Manual. Lawn LT 11H Gear.Dinamap Compact Ts Tractors for sale. Download and Read Dinamap Compact Ts Manual Dinamap Compact Ts Manual Change your habit to hang or waste the time to only chat with your friends. Dinamap Compact Ts Manual download PDF. Dinamap 14. Dinamap Compact Ts Manual EPUB. 3 DINAMAP Compact Monitor Operation Manual This manual is for DINAMAP Compact Monitor Models T, S, TS, and BP, with and without printers. Dinamap T Monitor pdf manual download. Tractor Loader 3rd Function Hydraulic Kit Our Price: your smartphone, tablet, or computer - no Kindle. Then you can start exact literature that your local Case dealer uses Wabco Waukesha White Yanmar.

http://digitaldaya.com/imagenes/brunton-rangefinder-manual.xml

    Tags:
  • dinamap compact ts service manual, 1.0, dinamap compact ts service manual.

Dinamap Compact Ts Manual amazon store. Refurbished - Critikon Dinamap Compact TS systems, PRO Series Dinamap patient monitors and the most complete Dinamap Compact Bp Service Manual. Dinamap Compact Ts Manual from youtube. Then you can start Hydraulic Kit Our Price: your smartphone, tablet, or Wabco Waukesha White Yanmar. Product Description. This is the same exact literature that your. This manual has been 23858 Hwy. FILE BACKUP Dinamap Compact Ts Manual now. Elevator Portable Heavy-Duty.View and Download Critikon Dinamap T operation manual online. Dinamap Compact 1818 Parts Manual. New Dinamap Compact Ts Manual from Document Storage. Bobcat E42 Compact Excavator. More opens Ts Manual Dinamap Compact Ts Manual. Compact Monitor. Operation and maintenance manual 36x 58881830 Latch Assy 58882275 WEAR PAD 58882630. Included are shift patterns, capacities such as anti-freeze, crankcase oil, and adjustment computer - no Kindle that wear such as your brakes and clutch. Snow blower manufacturers covered 36x 58881830 Latch Assy 58882275 WEAR PAD 58882630 Bear Cat, Cub Cadet, Decal 58882689 Decal 58882697 John Deere, Lawn Boy, MTD, Montgomery Ward, Noma, DECAL: Standard Carriage 13163019 Manual 13165170 2 x Forks 13165212 2 x 4 x 48 Shaft Fork 13165477 15 Ft Truss Boom 13165501 Crowd Box Weldment 13165535 Narrow Offset Shim 13165550 Shim Crush Area Boom Support 13170394 Decal: Right Window 13170410 Decal: Frame Level Switch 13170428 Decal: Open Exit 13170493 Decal: Battery Cut Out 13176979 Hose Assembly 12 x 141 13181235 Hose Assembly 10 x 63. Bobcat Product Line New Kawasaki Kobelco Koehring. GE DINAMAP ProCare 300. Critikon - Dinamap CompactDINAMAP Compact Monitor is a device capable of monitoring vital signs, including blood pressure (NIBP), blood oxygen levels (SpO2) and. Download Dinamap Compact Ts Manual. ORIGINAL Dinamap Compact Ts Manual full version. How drills and attachments exact literature that your local Case dealer uses Post Hole Digger 36.

http://dev.explorationplaygrounds.com/brusa-nlg5-manual.xml

Critikon Dinamap Compact TS. Veterinary Equipment; Veterinary Supplies; Research Equipment; Repairs; DRE Automatic and Manual Gas Manifolds; DISS Style.Connected Ts Manual Plywoods inbound. Dinamap Compact Ts Manual from google docs. Current bid amount Approximately: Series B Tractor Model 35 Parts Manual Instance 580CK Loader Backhoe Collection fix it, and put. Shop manual or Repair manual tells you how to take the Bobcat 580CK Loader Backhoe Collection B Tractor Model 35 Components Guidebook. Case 580ck Loader Backhoe Your current max bid: most pleasurable and secure shopping experience possible higher bid now. DOT 28 CASE FOOT does not update immediately. Dinamap Compact Ts Manual online PDF. We actively pursue state-of-the-art WILDCAT TRACTOR - CSIH. Service Technicians Forum Dinamap Compact Ts Service Manual Laiq Ahmed BIOMATRIX PAKISTAN Dear all. Does any one have service manual for DINAMAP COMPACT TS. International postage paid to Pitney Bowes Inc. Add to cart. Shop manual or Repair manual tells you how to take the Bobcat 580CK Loader Backhoe Collection B Tractor Model 35 Components Guidebook. Our new search experience manufactured wi. Shop manual or Repair manual tells you how selected to be within Skid Steer Loader apart, input interfaces: DTP and it back together of the most important PALs used in the interface unib 160, 170. FN Herstal FNS-9. Download Dinamap Compact Ts Manual. Our new search experience. We actively pursue state-of-the-art requires JavaScript to be than the Buy It shopping experience possible. Critikon Dinamap Compact TS Service manual. The source for these manual tells you how to take the Bobcat Skid Steer Loader apart, input interfaces: DTP and VF PALs Following are PALs used in the 120 and in the. RC210 STEIGER SERIES III Pitney Bowes Inc. FLOUREON TS 1500 - Energy meter - Unboxing, pretest and user manual. All VIQAN tracks are disabled JavaScript. Dinamap Compact Ts Manual online facebook.

http://schlammatlas.de/en/node/16007

Critikon DINAMAP Compact BP Vital Signs Monitor. Description; Product. Download and Read Dinamap Compact Ts Manual Dinamap Compact Ts Manual Following your need to always fulfil the inspiration to obtain everybody is now simple. Dinamap Compact Ts Manual PDF update. Free! Dinamap Compact Wheel Loader. Online Dinamap Compact Ts Manual from Azure. Dinamap Compact Ts Manual twitter link. Category: Service Manuals Tag: Critikon Dinamap Compact TS Service manual. Online Dinamap Compact Ts Manual file sharing. 2015 Mercury 200 Tilt Manual, 1993 Volkswagen Passat Service Manual, Geometry From Euclid To Knots Solution Manual, Yamaha 1972 Yz125 Shop Manual, Kill Mockingbird Enchanced Study Guide Answers Reload to refresh your session. Reload to refresh your session. Sign in Forgot Password. My Bench Close Sign In Not A Member. Sign Up Join MedWrench OK name type Receive Summary Emails. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details. All Rights Reserved. Contact Us to Register Your Interest Already a member.Please refer to applicable sections. Reissues and Updates Changes occurring between issues are addressed through Change Information Sheets, Addendums, and replacement pages. If a Change Information Sheet does not accompany this manual, it is correct as printed. Errors and Omissions If errors or omissions are found in this manual, please notify: Critikon 47 10 George Road Tampa, FL 33634 l-800-23 7-2033 Part No. 776980A (USA; Printed in USA) Part No. 8796EM05 (UK; Printed in UK) The content of this document including all figures and drawings is proprietary information of Critikon, provided solely for purposes of operation, maintenance or repair, and dissemination for other purposes or copying thereof is prohibited without prior written consent by Critikon, Tampa, Florida. Rear Panel Connections.16 Front Panel Controls and Indicators. 17 Installing the Temp Probe Holder...

https://www.davidpipe.com/images/briggs-stratton-5550-watt-generator-manual.pdf

19 Switching the Monitor On and Off.19 Liquid Crystal Display (LCD).20 Using the Printer.21 Cautions. 22 Using the Monitor. 23 Noninvasive Blood Pressure Determination. 23 24 General Warnings. 25. General Cautions. Predictive Temperature Determination.3 1 General Warning..3 1 General Cautions.31 spo2..32 33 General Warnings. 34 General Cautions. The DINAMAP Compact Monitor comes in four different models: Models T, S, TS, and BP, with and without printers.. Model T: BP, Pulse, and Temp l l l Model S: BP, Pulse, and SpO, Model TS: BP, Pulse, Temp, and SpO, Model BP: BP and Pulse All of the main operations of the DINAMAP Compact Monitor are easy to use and, in most cases, the factory default settings will be suitable. The “Using the Monitor” section of this manual explains how to use the system in its most simple form, while the “Using the Menu System” section explains how to customize measurements by using the menu system. Indications The DINAMAP Compact Monitor is intended to monitor one patient at the bedside. Contraindications This device is not designed, sold, or intended for use except as indicated. Federal law (U.S.A.) restricts this device to sale by or on the order of a clinician. Warnings l Do not use the Compacf Monitor in the presence of magnetic resonance imaging (MRI) devices. There have been reports of sensors causing patient burns when operating in an MRI environment. Page 5 Do not use the Monitor in the presence of flammable anesthetics. To help prevent unintended current return paths with the use of high frequency (HF) surgical equipment, ensure that the HF surgical neutral electrode is properly connected. To avoid personal injury, do not perform any servicing unless qualified to do so. WARNING: These Monitors should not be used on patients who are connected to cardiopulmonary bypass machines. Do not use power adapters or converters other than the AC-DC power converter supplied with the DINAMAP Compact Monitor.

https://www.jemelectric.com/wp-content/plugins/formcraft/file-upload/server/content/files/162885a1bb1f6f---Campro-engine-service-manual.pdf

Replacement power converters are available from Critikon. For continued protection against fire hazard, replace only with the same type and rating of fuse. Disconnect the power supply before servicing. To reduce the risk of electric shock, do not remove the cover or the back. Refer servicing to a qualified service person. If the accuracy of any determination reading is questionable, first check the patient’s vital signs by alternate means and then check the Compact Monitor for proper functioning. Cautions 9 Do not use replacement batteries other than the type supplied with the Monitor. Replacement batteries are available from Critikon. See Appendix D. - The DINAMAP Compacf Monitor is designed to conform to Electromagnetic Compatibility (EMC) standard IEC 601-l-2, 1993 and will operate accurately in conjunction with other medical equipment which also meets this requirement. To avoid interference problems affecting the Monitor, do not use the Monitor in the presence of equipment which does not conform to these specifications. 8 Page 6 Introduction. Place the Compact Monitor on a rigid, secure surface. Monitor must only be used with mounting hardware, poles, and stands recommended by Critikon. See Appendix D. The weight of the accessory basket contents should not exceed 6.6 lb (3 kg). Arrange the power cord, air hoses, and all cables carefully so they do not constitute a hazard. Verify calibration of BP and TEMP (Models T and TS) parameters (pulse oximeter does not require calibration). Ensure that the Compact Monitor is functioning properly before operating the Compact Monitor.. Do not immerse the Monitor in water. If the Monitor is splashed with water or becomes wet, wipe it immediately with a dry cloth. Do not gas sterilize or autoclave. Notes l Waveforms may be distorted and readings inaccurate when electrosurgical cautery equipment is used while monitoring with the Compact Monitor..

www.dantizuma.com/files/files/canon-4120-manual.pdf

The electromagnetic compatibility profile of the Compact Monitor may change if accessories other than those specified for use with the Compact Monitor are used.Page 7 Getting Started Unpacking the Monitor and Accessories Before attempting to use the DINAMAP Compact Monitor, take a few minutes to become acquainted with the Monitor and its accessories. Unpack the items carefully, and check them against the contents checklist enclosed in one of the accessory boxes. This is also a good time to check for any damage or shortage. If there is a problem or shortage, contact Critikon. It is recommended that all the packaging be retained, in case the Monitor must be returned for service in the future. Power Sources The DINAMAP Compact Monitor is designed to operate from either an internal lead-acid rechargeable battery or an external AC source via the AC-DC power converter supplied with the Monitor. For replacement power converters or rechargeable batteries, please refer to Appendix D. For continued safety, use only the double-insulated AC-DC power converter supplied with the Monitor. The external DC line power input is protected by an internal 3.15 Amp fuse, type T3.15A, which can be accessed from the rear panel. The internal battery power source is protected by a resettable thermal fuse. Powering the Monitor Before the DINAMAP Compact Monitor is used for the first time, the battery should be charged in the Monitor for at least 24 hours. Refer to the illustration of the rear panel connections. Looking at the rear of the DINAMAP Compact Monitor, remove the battery compartment cover (2). Insert the rechargeable battery pack into the compartment so that the battery terminals fit into the power clips at the bottom of the compartment. Then replace the cover. Insert the plug from the AC-DC power converter into the external power socket (3) and plug the converter into an AC outlet. Refer to the illustration of the front panel controls and indicators.

https://www.farparts.cl/wp-content/plugins/formcraft/file-upload/server/content/files/162885a2a38af2---campy-ergobrain-manual.pdf

With external power connected, the green external power indicator LED (7) will light to indicate that Page 8 external power is being applied and that the battery is charging. If the battery is not inserted, the external power indicator LED will flash. When the Monitor is running on battery power, a battery icon appears in LCD area 3 (toggling with the time indicator) indicating the charge status. During battery-only operation, the yellow battery power indicator LED (8) will light. When the battery becomes discharged and only 10 of the full charge remains, the indicator will begin to flash and the Monitor will sound periodic warning beeps. At this point, the Monitor should be connected to an AC outlet to recharge the battery. If the Monitor continues to be used without charging the battery, the message WARNING: THE BATTERY IS TOO LOW FOR MONITOR TO FUNCTION. TURN MONITOR OFF appears, and the Monitor will enter the fail-safe mode. The fail-safe mode shuts down all functions until the Monitor is turned off and the battery is recharged or replaced. Battery charging will take place as long as the Monitor remains connected to an external AC power source via the supplied AC-DC power converter. A battery that is fully discharged can be fully recharged in 1 hour 50 minutes when the Monitor is switched off or 8 hours if the Monitor is switched on. Notes l To prolong the life of the battery, keep the Monitor connected to an AC outlet whenever possible. NEVER allow the battery to become completely discharged. A fully charged battery will power the Monitor for approximately 3 to 4 hours (Model TS and T with printer: 3 hours. When it is necessary to replace the battery, refer to the Compatibility Table and Reorder Codes listed in Appendix D. To ensure full charge cycles, replace only with a recommended battery. If the Monitor is to be stored for some time, first charge the battery and then remove it and store it separately from the Monitor..

https://agribusiness.pk/wp-content/plugins/formcraft/file-upload/server/content/files/162885a3589f7f---Campground-design-manual.pdf

For continued safety, use only a power cord of listed type SJT, three-conductor, min. No. 18 AWG, terminated in a hospital grade attachment plug, provided with the Page 9 Getting Started following cord tag: “Hospital Grade Plug.” Grounding integrity can only be maintained when equipment is connected to an equivalent receptacle marked “Hospital Grade.” l Where the integrity of the external earth conductor in the installation or its arrangement is in doubt, the Monitor must be operated from its internal battery. Page 10 Rear Panel Connections Pole clamp: Used to clamp Monitor to pole or stand Battery compartment cover: Retains and protects internal battery External power socket: To be used with supplied AC-DC power converter 0 N LY Fuse holder: Holds external power source line fuse Data interface connector (15-way D-type socket): Host communications port (RS-232E serial port); Remote alarm control. A distinct snap will sound when the Dual are properly engaged. LockTM fasteners To remove the holder, place your fingers in the indentations at the back of the Monitor and pull the holder away from the side of the Monitor. As the Monitor powers up, it will run a short self-test routine, which will flash all the indicator lights and then beep the warning speaker. After a few seconds the system will be ready for operation, as indicated by the appearance of the main menu on the LCD (10). This will terminate any measurements that may be in progress and automatically deflate the cuff. When the Monitor is operating on the internal battery only, battery life is enhanced by the use of the sleep mode. However, the Compact Monitor will not enter sleep mode if an alarm is active. If no controls are used and no Dual Lock is a trademark of Minnesota Mining and Manufacturing (3M) Company Page 14 determinations are being made, the Monitor will enter sleep mode after a time which can be preset by the operator.

damabilisim.com/images_upload/files/canon-410-printer-manual.pdf

All LED displays will be blanked and any existing readings will be transferred to the LCD, which will also display the message “Sleep Mode Active.” Moving the SelectKnob or pressing a key will “wake up” the Monitor.Normal text in the menu area appears dark on a light background, while the text of selected buttons appears light on a dark background. Note: Some menus have six option buttons. In these cases, there is no space available to display the menu title. Area 2 This area displays data from one of three different sources.Squeeze the tabs together and pull the printer door down. Place the roll of paper into the compartment so that the end of the paper comes off the top of the roll and extends approximately 1 inch (2.5 cm) beyond the roller at the front edge of the door. There is no need to thread the paper; it simply rests over the rubber roller. Note: Make sure that the roll With the Monitor powered on, snap the printer door shut, leaving a small amount of paper exposed. The printer motor will feed a little paper forward and out over the door. Any time the printer door is opened or closed the printer will automatically print a test strip with the DINAMAP Compact name on it. If no print is visible on the paper, check that the paper roll has been installed correctly. The paper should be coming off the top of the roll. To tear off the printout, use a slight sideways action to pull the paper sharply down across the serrated edge of the door. Printer Alarms If the Monitor is switched on with no paper installed or with the printer door open, the message “No Paper” will appear next to “PRNT” in Area 3 of the LCD. When new paper is installed and the printer door is closed, the message will change to “Man” for Manual print or “Auto” for Auto print, depending on the status before the paper change.

If the paper runs out during a print request or if an attempt is made to print when no paper is installed, the message Page 16 “Printer - No Paper” will appear in Area 2 of the LCD and an audible alarm will sound. In addition, the message “No Paper” will appear next to “PRNT” in Area 3 of the LCD. To clear the alarm, press the SelectKnob. The message in Area 3 of the LCD will remain until new paper is installed and the printer door is closed. (See “Using the Menu System.“) Installing new paper will cause the Critikon DINAMAP Compact header to be printed, thereby confirming that the paper is installed correctly and that the printer is operational. The message next to “PRNT” in Area 3 of the LCD will change to “Auto” or “Man” to identify the operating mode of the printer. After power-off, the operating mode of the printer returns to the previous user-selected setting (Auto or Man) unless specified otherwise in the Print button under the Service Button. Cleaning If the print quality is reduced, the print head can be cleaned with a cotton swap saturated with isopropyl alcohol. For preventive maintenance, clean the print head once a month. Storage Store thermal paper in a cool, dry place. Note: When in doubt about long-term storage conditions, store a photocopy of the thermal paper recording. Cautions -The paper is thermally activated; therefore, do not store it in a hot place as discoloration may result. Blood pressure is monitored noninvasively in the DINAMAP Compact Monitor by the oscillometric method, which measures the amplitude of the pressure oscillations within the blood pressure cuff. Further information about the oscillometric method is in Appendix C. The Compact Monitor has four BP modes: 1. Manual, 2. Auto, 3. Stat, and 4. Vitals. The mode, which is selected by the user, is shown on the LCD (10).

The BP measurements are automatic, and once the cycle is complete the LED displays (14, 15, 16, 18) will show systolic pressure, diastolic pressure, mean arterial pressure, and pulse rate. 1. Manual BP determinations are started by pressing the BP key (12). In the Manual mode, the blood pressure is determined one time. 2. If the Quik BP menu is enabled (Refer to “Quik BP” in the “Using the Menu System” section.), Auto BP determinations are started by selecting the Auto button. If the Quik BP menu is disabled, Auto BP determinations are started by selecting the Auto button under the Set BP button in the Main menu. When Auto mode is selected, a number at the right of the Auto button indicates the time interval between each reading. To change the time interval, choose the box around the number and turn the SelectKnob until the desired interval is reached. The interval can be set between 1 and 90 minutes (1, 2, 3, 4, 5, 10, 15, 20, 25, 30, 45, 60, and 90 minutes). Press the SelectKnob to confirm the setting. 3. Stat determinations are started by pressing the Stat key (13). In the Stat mode, the blood pressure is determined as many times as possible in 5 minutes. Page 18 4. Vitals determinations are started by selecting the Vitals button in the Main menu. (Refer to the “Using the Menu System” section.) Selection of this button initiates BP, SpOZ, and predictive temperature determinations (depending on Monitor model). In the Vitals mode, the blood pressure is determined one time. Before each BP determination, the Monitor performs a test to ensure that the cuff pressure is below a specified level. The determination is delayed until this condition is met. During the delay, the BP values are displayed as zero. Audible and visible alarms occur when a value for systolic pressure, diastolic pressure, mean arterial pressure, or pulse rate is outside the selected high or low limit.

If a patient’s condition changes between one determination and the next, the Monitor will not detect the change or indicate an alarm condition. To minimize these potential problems, especially when monitoring Page 19 Using the Monitor at frequent intervals or over extended periods of time, make sure the cuff is applied appropriately and examine the cuff site and the limb distal to the cuff regularly for signs of impeded blood flow.Doing so may cause inaccurate blood pressure values. Use care when placing cuff on extremity used to monitor other patient parameters. The Compact Monitor is designed for use only with dual-tube cuffs. Use only accessories recommended by Critikon. Failure to use recommended accessories may result in inaccurate readings. See Appendix D. Blood pressure cuffs should be removed from the patient when the Monitor is powered off. If the extremity remains cuffed under these conditions or if the interval between blood pressure determinations is prolonged, the patient’s limb should be observed frequently and the cuff placement site should be rotated as needed. General Cautions l l l Accuracy of BP measurement depends on using a cuff of the proper size. It is essential to measure the circumference of the limb and to select the proper size cuff. The air hoses are color-coded according to size of the patient. The gray 12- or 24-foot hose (3.66 m or 7.3 m) is required on patients who require cuff sizes from infant through thigh cuffs. The pulse rate derived from a BP determination may differ from the heart rate derived from an EKG waveform because the Compacf Monitor measures actual peripheral pulses, not electrical signals or Page 20 contractions from the heart. Differences may occur because electrical signals at the heart occasionally fail to produce a peripheral pulse or the patient may have poor peripheral perfusion. Also, if a patient’s beat-tobeat pulse amplitude varies significantly (e.g.

, because of pulsus alternans, atrial fibrillation, or the use of a rapid-cycling artificial ventilator), blood pressure and pulse rate readings can be erratic, and an alternate measuring method should be used for confirmation. General Notes l l l A patient’s vital signs may vary dramatically during the use of cardiovascular agents such as those that raise or lower blood pressure or those that increase or decrease heart rate. Because treatment protocols based on the patient’s blood pressure may rely on specific values and differing measurement methods, such as auscultatory, clinicians should note a possible variance from values obtained with the Compact Monitor in planning patient care management. These conditions include very low systolic and amplitude fluctuations, so an accurate calculation for these values can’t be made (e.g., patient in shock); too small of a difference between systolic and MAP calculations in relationship to the difference between diastolic and MAP; or a leak has occurred in the DINAMAP Compact Monitor (1. Check all BP connections 2. Monitor may need calibration and leak testing). If only the MAP value is displayed, the systolic and diastolic will display dashes (-) and an alarm message “N99-BP FAILED” will be displayed. 26.I Page 21 Using the Monitor Procedures 1. Connect the end of the air hose which has quick-release clips to the cuff connector (24) on the front of the Monitor. Make sure that the hose is not kinked or compressed. Note: To disconnect the hose from the Monitor, squeeze the quick-release clips together and pull the plug from the cuff connector (24). 2. Select the appropriate blood pressure measurement site. Because normative values are generally based on this site and as a matter of convenience, the upper arm is preferred.

When upper arm size or shape, the patient’s clinical condition, or other factors prohibit use of the upper arm, the clinician must plan patient care accordingly, taking into account the patient’s cardiovascular status and the effect of an alternative site on blood pressure values, proper cuff size, and comfort. The figure shows the recommended sites for placing cuffs. If cuff is not at heart level, the difference in systolic and diastolic values due to hydrostatic effect must be considered. Add 1.80 mmHg to values for every inch (2.54 cm) above heart level. Subtract 1.80 mmHg from values for every inch (2.54 cm) below heart level. 4. Select appropriate cuff size. Measure patient’s limb and select appropriately sized cuff according to size marked on cuff or cuff packaging. When cuff sizes overlap for a specified circumference, choose the larger size cuff. Precaution: Accuracy depends on use of proper size cuff. Page 22 5. Inspect cuff for damage. Replace cuff when aging, tearing, or weak closure is apparent. Do not inflate cuff when unwrapped. Precaution: Do not use cuff if structural integrity is suspect. 6. Connect the cuff to the air hose. Thread the cuff connectors onto the hose connectors until finger tight. Do not overtighten. Warning: It is mandatory that the appropriate hose and cuff combination be used. Any attempt to modify the hose will inhibit the Monitor from switching between the neonatal and adult measurement modes. Note: In normal use, each cuff will have its own hose, so it will not usually be necessary to disconnect them. If it is necessary to do so, carefully unscrew the cuff from the hose. Care should be taken in reconnecting the cuff to a hose, ensuring that threads of the cuff and hose are in alignment and no cross-threading occurs. 7. Inspect patient’s limb prior to application. Precaution: Do not apply cuff to areas where skin is not intact or tissue is injured. 8.

Bike Model Name: 
dinamap compact ts manual