hw2000i manual

Failure to closely follow these instructions can result in circumstances leading to death, serious injury, and property damage. Samples of these labels are provided below. Should any of these labels become illegible or damaged, call 1-888-HWHELP1 (494-3571) for replacements. FIGURE 1: HW1000i Model Label Locations FIGURE 2: HW2000i Model Label Locations PRODUCT LABEL. MAINTENEZ LA ZONE CLAIRE. 101588A CUIDADO El aire entra en el fondo de la unidad. ANYONE using this generator must read, understand, and follow all safety and operation instructions provided in the product manual. Failure to closely follow these instructions can result in circumstances leading to death, serious injury, and property damage. Improper connections to a building's electrical system can be deadly. The information below is provided for reference only. Refer to “OPERATION” on page 11 for instructions on operating generator. Generator is heavy! Obtain assistance to lift the generator to avoid back or other bodily injury. Accessories Oil Drain Pipe Oil Fill Container. Ground Terminal Oil Alert Indicator Light Connects generator to ground wire for grounding protection. Turns the engine ON or OFF. E—Recoil Starter Handle Efficiency Mode Switch Starts engine. When Efficiency Mode is ON, the engine speed will automati- F—Back Maintenance Cover cally adjust based on the connected load, resulting in better Provides access to air filter, fuel filter, and oil fill cap. Generator exhaust contains carbon monoxide. This is a poi- son you cannot see or smell. NOTE: Place the choke in the OFF position when the HW1000i has a warm engine. Before starting generator, be sure to thoroughly read all information provided in this Owner’s Manual. Set the efficiency mode switch to the OFF position. FIGURE 13: Output Ready Indicator Light (HW1000i model) FIGURE 11: Prime Engine Allow the engine to run continuously and warm up NOTE:. The oil alert system DC power and AC power can be used at the same time.

http://xn----0tbbbfo0f.xn--p1ai/userfiles/8711a-manual.xml

    Tags:
  • hw2000i manual, hw2000i parts manual, hw2000i manual, hw2000i manual, hw2000i manual, hw 2000 manual, honeywell hw2000i manual.

Perform service and inspection at the intervals shown in the Generator Maintenance Schedule (see Table 3). Using a generator indoors CAN KILL YOU IN MINUTES. Accidental starting of generator can cause severe injury or Generator exhaust contains carbon monoxide. NOTICE Engine oil is a major factor affecting engine performance and service life.Insert the flexible hose directly into the oil fill hole and Frequent or prolonged contact with engine oil may cause skin fill to the innermost thread of the crankcase. Generator is heavy! Obtain assistance to lift the generator to avoid back or other bodily injury. Return the unit to the upright position. Remove the oil drain pipe. Before each use, fill the fuel tank with recommended fuel. DO NOT OVERFILL. Fuel and fuel vapors are extremely flammable and explosive under certain conditions. Gasoline containing methanol must contain co-solvents and corrosion NOTE:. Never run the generator without the air cleaner assembly properly attached. Clean the air cleaner filter every 50 hours of generator operation. Cleaning Spark Arrestor Screen (HW2000i Model Only) Muffler reaches temperatures that can cause serious burns if touched. NEVER touch hot surfaces. The generator muffler is equipped with a spark arrestor screen, which must be cleaned according to the mainte- FIGURE 37: Excess Oil Removal nance schedule (Table 3). To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. If the engine has been running, the muffler will reach temperatures that could cause severe burns. Hot engine or exhaust system can cause serious burns or fires. Cool generator completely before Fuel and its vapors are extremely flammable and transporting or storing.Do not leave generator inside vehicle during high temperatures. Failure to closely follow these instructions can result in circumstances leading to death, serious injury, and property damage. Using a generator indoors CAN KILL YOU IN MINUTES.

http://happysteelindustry.com/userfiles/8712et-manual.xml

Do not return your generator to place of purchase for service. Any replacement part that is equivalent in per- formance and durability may be used for maintenance or repairs. HW1000i HW2000i Part Name Part Number Part Number 120V Outlet(s) 101582A 101626A Air Filter 101567A 101611A Carburetor Assembly 101579A 101623A Cover, Back Maintenance 101573A 101616A Cover, Top Maintenance 101574A. Honeywell International Inc. We have 3 Honeywell HW2000i - Portable Inverter Generator manuals available for free PDF download: Owner's Manual, Specifications. Producing 2000 watts of power and weighing only 58 lbs., this gasoline pow- ered unit will run 5 hours on a full tank. The HW2000i outputs both 120V outlet power and 12V DC power. For portable power you can take anywhere, the Honeywell HW2000i is just the right size for you. Lightweight, compact design, quiet operation and clean power. AC and DC indicator lights. Offers complete portability. Inverters: T ruly Portable Power When you are r eady to go camping, tailgating or just need a portable power supply, the Honeywell HW2000i provides ef?cient, quiet and clean power for all yo ur r ecrea tiona l nee ds. P ro ducin g 2000 watts of power and weighing only 58 lbs., this gasoline pow- ered unit will run 5 hours on a full tank. The HW2000i outputs both 120V outlet power and 12V DC power. The HW2000i is an inverter generator so it provides clean power to run high performance electronics like TV's and computer equipment. For portable power you can take anywhere, the Honeywell HW2000i is just the right size for you. 1 T o power a combination of these, refer to the wattage chart in your owner's manual.If you are here, it was rather the case. However, you are not the only person having problems with keeping the operation manual of all household devices. Below are few guidelines regarding how and why you should collect the product manuals.

http://fscl.ru/content/bosch-hbn331eob-user-manual

However, we believe that the manuals should include the most important and needed information about Honeywell HW2000i, not to discourage the user to read. Obviously, if a device Honeywell HW2000i has multiple advanced functions, we will not avoid a high amount of information in this document. Then, it will be much easier to find it than look through the purchase boxes which have already been thrown away by you or any other of household members. It will be enough to clear the drawer once in a year and throw away any manuals of the devices you do not use anymore. Thus, you can avoid storing any unnecessary documents and keep only those which are valid. You can also download and print the manual Honeywell HW2000i to place it in your drawer. Login to post However, if it needs service I would look online for a commercial service provider who has been in business for many years and is experienced in diesel generators. Look online for generator repair companies. While it's still unlikely they'll have a manual for it, most likely they will still be able to provide service for it. A Google search came up with this site: Good luckJust being curious whether you have filled up oil in the crankcase. The manual says there is a engine protection system that operates if engine oil is not at the right level. Make sure you have used the correct grade of engine oil.They probably have a download you can get!Answer questions, earn points and help others. Discover everything Scribd has to offer, including books and audiobooks from major publishers. Start Free Trial Cancel anytime. Honeywell 2000i Inverter Generator - Parts Manual Uploaded by josh 0 ratings 0 found this document useful (0 votes) 2K views 1 page Document Information click to expand document information Description: Parts manual for Honeywell 2000i inverter generator. (Looks like Honda unit).

http://ambarevleri.com/images/bt-paragon-500-user-manual.pdf

Report this Document Download Now Save Save Honeywell 2000i Inverter Generator - Parts Manual For Later 0 ratings 0 found this document useful (0 votes) 2K views 1 page Honeywell 2000i Inverter Generator - Parts Manual Uploaded by josh Description: Parts manual for Honeywell 2000i inverter generator. (Looks like Honda unit). Complete PDF Full description Save Save Honeywell 2000i Inverter Generator - Parts Manual For Later 0 0 found this document useful, Mark this document as useful 0 0 found this document not useful, Mark this document as not useful Embed Share Print Download Now Jump to Page You are on page 1 of 1 Search inside document Scribd members can read and download full documents. Your first days are free. Continue Reading with Trial Share this document Share or Embed Document Sharing Options Share on Facebook, opens a new window Share on Twitter, opens a new window Share on LinkedIn, opens a new window Share with Email, opens mail client Copy Text Related Interests Rotating Machines Technology Vehicle Parts Manufactured Goods Propulsion Footer Menu Back To Top About About Scribd Press Our blog Join our team. Browse Books Site Directory Site Language: English Change Language English Change Language. To read more about the cookies we use, see our privacy policy. Click the button below, then find your model pictured in the list shown and click the 'Write a Review' Link. Pour obtenir des renseignements sur les produits ou pour du soutien technique, visitez notre site a l’adresse www.honeywellgenerators.com (en anglais seulement) ou composez notre numero sans frais 1-888-HWHELP1 (494-3571). Si tiene preguntas acerca de los productos o requiere de asistencia, visite www.honeywellgenerators.com o llame gratis al 1-888-HWHELP1 (494-3571). Congratulations on owning a Honeywell inverter generator. WARNING This manual contains important instructions for operating this generator.

https://www.birdandwildlifeteam.com/wp-content/plugins/formcraft/file-upload/server/content/files/1629201d4839e9---9120-manual.pdf

For your safety, and the safety of others, read this manual thoroughly before operating the generator. Failure to properly follow all instructions and precautions can cause you and others to be seriously hurt or killed. Please use the spaces provided below to record important information about your generator. You may be asked to provide this information should you require product service or support. Identification information specific to your generator (model number and serial number) can be found on the generator nameplate. Honeywell International Inc.Failure to closely follow these instructions can result in circumstances leading to death, serious injury, and property damage. Hazard Symbols and Meanings NOTE: Since there are many variations in the circumstances surrounding the installation, operation, service, and maintenance of this generator, we cannot possibly anticipate or provide advice or safety messages to cover every situation. All safety messages are introduced by a signal word indicating the hazard level. DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury to the operator or to bystanders. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury to the operator or to bystanders. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in moderate or minor injury to the operator or to bystanders. NOTICE Indicates a situation which, if not avoided, may result in damage to the generator components. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open. Only use OUTSIDE and far away from windows, doors, and vents. www.honeywellgenerators.com 1 Safety Messages Safety Messages Electric Shock Hazards WARNING WARNING Generators produce powerful voltage that can cause death or great physical harm.

BANGDIENTUNHK.COM/upload/files/comtech-ut-4505-manual.pdf

Keep the generator out of reach of children, pets, and untrained people. Generator must be installed by a qualified electrician and connected to transfer equipment as a separately derived system in accordance with the National Electrical Code, NFPA 70. Generator shall be connected through transfer equipment that switches all conductors other than the equipment grounding conductor. Frame of the generator shall be connected to an approved grounding electrode. NEVER enclose the generator in any structure. Keep generator at least 6 feet (2 meters) away from buildings, other equipment, and combustible materials during operation. NEVER fill fuel tank while the engine is running. Turn generator OFF and allow to cool before filling with fuel. NEVER smoke or allow flames or sparks near the generator or where gasoline is stored. NEVER overfill the fuel tank (there should be no fuel in the filler neck). After refueling, make sure the tank cap is closed properly and securely. Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may ignite. If any fuel is spilled, be sure the area is dry before starting the engine. Avoid repeated or prolonged contact with skin or breathing of vapor. www.honeywellgenerators.com NEVER modify generator in any way. NEVER tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed. During and after the use of the generator, inspect the generator as well as extension cords and power supply cords connected to it for damage resulting from vibration. Have damaged items repaired or replaced as necessary. Even a properly connected portable generator can become overloaded. Samples of these labels are provided below.

http://mountmedpharmacy.co.za/wp-content/plugins/formcraft/file-upload/server/content/files/1629201e2329ba---9125-ups-manual.pdf

A A B E C 900 RATED WATTS G 1000 MAXIMUM WATTS NEUTRAL FLOATING NEUTRE FLOTTANT A D H FIGURE 2: HW1000i Model Label Locations F B E C G 2000 RATED WATTS 2100 MAXIMUM WATTS NEUTRAL FLOATING NEUTRE FLOTTANT A D H FIGURE 3: HW2000i Model Label Locations PRODUCT LABEL PART NUMBER DANGER Using a generator indoors CAN KILL YOU IN MINUTES. Only use OUTSIDE and far away from windows, doors, and vents. DANGER A L’utilisation d’une generatrice a l’interieur PEUT VOUS TUER EN QUELQUES MINUTES. Les generatrices rejettent du monoxyde de carbone, un gaz toxique invisible et inodore. 101589B NE JAMAIS utiliser la generatrice a l’interieur d’une residence ou d’un garage MEME SI les portes et les fenetres sont ouvertes. Utiliser uniquement a L’EXTERIEUR et loin des fenetres, portes et events. PELIGRO Usar el generator en interiores LO PUEDE MATAR EN MINUTOS. El escape del generator contiene monoxido de carbono. Este gas es un veneno que no se puede ver ni oler. NUNCA use el generador dentro del hogar o el garaje, AUN si las puertas y ventanas estan abiertas. Solo uselo en EXTERIORES y lejos de ventilaciones, puertas y ventanas abiertas. DO NOT BLOCK. ATTENTION Entree d’air sur le bas de l’inverseur.WARNING ANYONE using this generator must read, understand, and follow all safety and operation instructions provided in the product manual. Failure to closely follow these instructions can result in circumstances leading to death, serious injury, and property damage. Package Checklist CAUTION Generator is heavy. Obtain assistance to lift the generator to avoid back or other bodily injury. 1. Set carton on a rigid, flat surface. 2. Remove carton contents. 3. Remove and discard silica gel pack. 4. Verify all of the following items are included in the generator package. Inverter Generator. Owner’s Manual ? Oil Fill Container. Tool Kit ? Oil Drain Pipe ? Spark Plug Wrench ? Screwdriver Handle. Screwdriver Universal Bit 5. Inspect for damage.

http://exactblue.com/wp-content/plugins/formcraft/file-upload/server/content/files/1629201e760585---912mk2-manual.pdf

Carefully inspect generator for any damage that may have occurred during shipment. If loss or damage is noted after opening, separate damaged materials and call 1-888-HWHELP1 (494-3571). 6. Remove the “No OIl Fill” tag from the generator. See “Adding Engine Oil” on page 18. CAUTION! OIL HAS BEEN DRAINED FOR SHIPPING Failure to fill engine with oil before starting engine will result in permanent damage and will void engine warranty. Write down the identification information specific to your generator in the spaces provided on the inside cover of this Owner’s Manual. This information is located on the generator nameplate (see illustration below). Special Requirements There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of generator. Using Generator for Back-up Power DANGER Improper connections of the generator to a building’s electrical system can be deadly. 2000 RATED WATTS 2100 MAXIMUM WATTS NEUTRAL FLOATING NEUTRE FLOTTANT FIGURE 5: Ground Terminal (HW2000i Model Illustrated) NOTE: The generator is neutral floating which means the ground terminal on the generator is not connected to the AC neutral wire in the generator. If using a receptacle tester, it will not show the same ground circuit condition as for a home receptacle. Electrical current from generator can feedback into utility lines. Such feedback may electrocute utility company workers or others who contact utility lines during a power outage. Electrical current can feedback into generator. CAUTION The information below is provided for reference only. See “Grounding the Generator” on page 6. 3. Breakers Protects circuits from damage caused by overload or short-circuit by stopping flow of electricity from generator to the appliance. If there is no power at outlets, see “Troubleshooting” on page 29. 8 www.honeywellgenerators.com Overload Indicator Light Illuminates red when the generator is overloaded.

BAINIHU.COM/upfiles/editor/files/comtech-turboip-g2-manual.pdf

Turn the generator off immediately and determine the reason for the overload. 5. Output Indicator Light Illuminates green when the generator is running under normal operating conditions. 6. Oil Alert Indicator Light Illuminates red when low oil conditions are present and the generator is running (or while recoil is pulled). The engine will automatically stop to prevent generator damage. B—Top Maintenance Cover Provides access to the engine spark plug. C—Muffler Provides outlet for engine exhaust. WARNING Muffler reaches temperatures that can cause serious burns if touched. E—Recoil Starter Handle Starts engine. F—Back Maintenance Cover Provides access to air filter, fuel filter, and oil fill cap. G—Fuel Cap Provides a secure seal on fuel tank. The HW1000i model has a vented fuel cap. H—Fuel Valve Controls flow of fuel from fuel tank to carburetor. I— Choke Control Controls choke valve. Use generator only outdoors and far away from windows, doors, and vents. WARNING If generator is placed on an uneven or flexible surface, generator could tilt or overturn, causing fuel to spill from gas tank. If generator is tilted or overturned, fuel spillage may result. Also, if generator is overturned or sinks into a soft surface, sand, dirt, or water may enter generator. WARNING NEVER operate generator in rain or snow, or when the generator is set on wet surface. WARNING Preparing for Operation DANGER CARBON MONOXIDE Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. Deadly levels of carbon monoxide can build up in these areas. These openings can pull in generator exhaust. Even when you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or batterybackup CO alarm in the home. If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY. See a doctor.

You could have carbon monoxide poisoning. Before starting generator, complete the following preparation tasks. Be sure generator is placed outdoors in a well ventilated area.In good condition. ? Rated for outdoor use and match amperage and voltage ratings of generator outlet. ? Equipped with plugs that have a ground terminal. www.honeywellgenerators.com 11 Starting Generator Starting Generator Starting Generator 4. Move the choke to the ON position. NOTE: WARNING Thoroughly read and understand all information provided in this Owner’s Manual before operating generator. Place the choke in the OFF position when the HW1000i has a warm engine. 5. Set the efficiency mode switch to the OFF position.FIGURE 10: Engine Control Switch 7. HW1000i Model Only: Turn the fuel cap vent to the ON position. OF F ON FIGURE 11: Fuel Cap Vent — ON Position 8. While securing the generator with one hand, grip the recoil starter handle and pull slowly until you feel slight resistance. (HW2000i model illustrated) FIGURE 7: Air Intake - DO NOT BLOCK NOTICE Blocking the air flow may cause damage to the generator. 2. Turn the fuel valve to the ON position. NOTE: Apply swift pulls to start the engine, carefully returning the recoil starter handle to the original position. NOTICE To prevent damage to the generator, do not allow the recoil starter handle to snap back against the engine. After the engine starts, let run for 2-5 seconds and then slowly move the choke to the OFF position. 11. After starting, confirm the output ready indicator light Connecting Appliances 1. Turn off and unplug all appliances to be plugged into the generator. 2. Start the generator (see “Starting Generator” on page 12). 3. Plug in and turn on appliances. Monitor the overload indicator light. If the overload indicator illuminates longer than 4 seconds, STOP THE ENGINE IMMEDIATELY. Do not restart generator until the reason for the overload or appliance short circuit is corrected.

FIGURE 13: Output Ready Indicator Light (HW1000i Model) 12. Allow the engine to run continuously and warm up before connecting any appliance. FIGURE 14: Overload Indicator Light (HW1000i Model) CAUTION Substantial overloading that continuously lights the overload indicator light may damage the generator. Marginal overloading that temporarily lights the overload indicator light may shorten the service life of the generator. If appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it OFF immediately. Disconnect appliance and determine whether problem is appliance, or if rated load capacity of generator has been exceeded. 4. Set the efficiency mode switch to the ON position. FIGURE 15: Efficiency Mode Switch Stopping Generator In an emergency: Press the engine control switch to the STOP position. In normal use: 1. Turn OFF any connected appliances and unplug any connected power cords. 2. Allow the generator to run for 2-3 minutes. 3. Press the engine control switch to the STOP position. 4. Turn the fuel valve to the OFF position. 5. Turn the fuel cap vent to the OFF position (HW1000i model only). The oil alert system will stop the engine automatically before the crankcase oil gets below the safety line. The engine will not restart until the required amount of engine oil is added. NOTE: Oil alert indicator light only illuminates while generator is running or while recoil is pulled. Power rating information can usually be found on an appliance’s product label, stamped inside, or on the back of the appliance. See Table 2 for a listing of average appliance wattage requirements. NEVER overload: Circuit breakers will stop the flow of electricity between the generator and appliance if the generator is overloaded. Check circuit breaker for “tripped’ position. Reduce the load on the receptacle(s) and reset the breaker.

Pay attention to appliance operation: If appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it OFF immediately. Disconnect the appliance and determine whether the problem is the appliance, or if rated load capacity of the generator has been exceeded. Use suitable extension cords: If using an extension cord to connect appliances to the generator, use only UL-listed, three-prong extension cords. Use the below area to calculate both the running wattage and additional starting wattage for your appliances. Running wattage is the amount of power needed to run the appliances continually. Additional starting wattage is the power needed to start appliances with electric motors. These numbers are best obtained from the appliance label, operating manuals, or contacting the manufacturer. The Appliance Wattage Information chart in this manual is also available for reference. 2. Add together the Running Watts and enter the total in the Total Running Watts box. 3. Enter the Additional Starting Watts of the one appliance that uses the highest starting wattage (see gray box below) and enter the number in the Highest Additional Starting Watts box. 4. Add together the Total Running Watts and Highest Additional Starting Watts and enter the total in the TOTAL STARTING WATTS box. 5. Use this number to verify the selected appliances can be powered without exceeding the generator capacity. Appliance TABLE 2. Typical Appliance Running Wattages EXAMPLE Appliance Television Computer, Laptop Air Conditioner, Window Running Watts 65 100 600 Additional Starting Watts --1200 Total Running Watts 765 Highest Additional Starting Watts 1200 TOTAL STARTING WATTS 1965 Generator must produce at least 765 running watts and able to provide 1965 starting watts. Perform service and inspection at the intervals shown in the Generator Maintenance Schedule (see Table 3). DANGER WARNING Using a generator indoors CAN KILL YOU IN MINUTES.

Accidental starting of generator can cause severe injury or death. Before performing maintenance, disconnect spark plug cap from spark plug. WARNING Only use OUTSIDE and NEVER use inside a home far away from windows, or garage, EVEN IF doors doors, and vents. If engine must be run, be sure area is well ventilated. NOTICE Maintenance, replacement, or repair of the emission control devices and systems may be performed by any non-road engine repair establishment or individual. Improper maintenance, or failure to correct a problem before operation, can cause a malfunction in which you can be seriously hurt or killed. Always follow inspection and maintenance recommendations and schedules in this owner's manual. NOTICE The maintenance schedule applies to normal operating conditions. If you operate generator under severe conditions, such as sustained high-load or high-temperature, or use it in unusually wet or dusty conditions, consult your servicing dealer for recommendations applicable to your individual needs and use. Clean more often when using generator in dusty areas. HW2000i model only. It is recommended that this maintenance task be performed by a service dealer. NOTICE Engine oil is a major factor affecting engine performance and service life. Refill engine oil if oil level is low. Engine Oil Recommendations Use 4-stroke oil, or equivalent high detergent, premium quality motor oil certified to meet or exceed U.S. automobile manufacturer's requirements for API Performance Class SF or better. SAE 15W-40 is recommended for general, all-temperature use. FIGURE 18: Oil Fill Cap Removal (HW2000i Model) 6. Check the oil level is up to the innermost thread of the crankcase. 15W-40 FIGURE 17: Recommended Oil Viscosity Checking Engine Oil Level To check engine oil level: 1. Stop the generator if the engine is running. WARNING ALWAYS stop engine before removing the oil fill cap. Crankcase pressure can cause hot engine oil to spray out of engine fill hole.

Hot engine oil can cause severe burns. 2. Place the generator on a flat, level surface. 3. Remove the back maintenance cover using the Phillips end of the universal screwdriver bit. 4. 18 Using a clean cloth, wipe around the oil fill cap area to remove dirt and debris. www.honeywellgenerators.com FIGURE 19: Oil Fill Measurement To add engine oil: During initial fill or when the oil level is low, add oil (see “Engine Oil Recommendations”) to the oil fill container (included). To change engine oil, you will need. Oil drain pipe ? Oil fill container. Screwdriver handle. Screwdriver universal bit FIGURE 20: Adding Engine Oil. New (unused) engine oil NOTICE. Place the generator on a flat, level, slightly raised surface (HW2000i model illustrated). CAUTION 10. Reinstall the oil fill cap until fully tightened, center the Generator is heavy. Obtain assistance to lift the generator to avoid back or other bodily injury.FIGURE 22: Generator on Raised Surface (HW2000i Model) FIGURE 21: Oil Fill Cap Installation 2. Drain the fuel into a suitable container (see page 27). 3. Start the engine and run until warm. 4. Stop the engine and place the engine switch in the OFF position. Crankcase pressure can cause hot engine oil to spray out of the engine fill hole. FIGURE 25: Drain Oil CAUTION FIGURE 23: Oil Drain Pan 7. Using a clean cloth, wipe around the oil fill cap area to remove dirt and debris. 8. Remove the oil fill cap. Slowly pour oil into the oil fill hole. Check the oil level is up to the innermost thread of the crankcase. Engine Fuel Before each use, fill the fuel tank with recommended fuel. DO NOT OVERFILL. DANGER Fuel and fuel vapors are extremely flammable and explosive under certain conditions. FIGURE 27: Oil Fill Measurement 16. If swallowed, seek medical treatment immediately. Do not induce vomiting if fuel is swallowed. For skin contact, wash with soap and water immediately. For eye contact, immediately flush eyes with clean water and seek medical attention.